Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
2.
JGH Open ; 7(12): 869-874, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38162840

ABSTRACT

Background and Aim: Recently, the use of various endoscopic procedures performed under X-ray fluoroscopy guidance has increased. With the popularization of such procedures, diagnostic reference levels (DRLs) have been widely accepted as the global standard for various procedures with ionizing radiation. The Radiation Exposure from Gastrointestinal Fluoroscopic Procedures (REX-GI) study aimed to prospectively collect actual radiation exposure (RE) data and establish DRLs in gastrointestinal endoscopy units. In this post hoc analysis of the REX-GI study, we established DRLs for each disease site by analyzing cases of gastrointestinal enteral metallic stent placement. Methods: The REX-GI study was a multicenter, prospective observational study conducted to collect actual RE data during gastrointestinal enteral metallic stent placement. To establish DRL values for three disease sites, namely the esophagus, gastroduodenum, and colon, we examined fluoroscopy time (FT; min), number of X-ray images, air kerma at the patient entrance reference point (K a,r; mGy), and the air kerma-area product (P KA; Gy cm2) during enteral metallic stent placement. Results: Five-hundred and twenty-three stenting procedures were performed. The DRL values of FT (min) and the number of X-ray images for the esophagus/gastroduodenum/colon were 9/16/18 min and 9/15/11 min, respectively. Furthermore, the DRL values of K a,r and P KA for each disease site were 43.3/120/124 mGy and 10.3/36.6/48.4 Gy cm2, respectively. Among the procedures, esophageal stents were significantly associated with the lowest values (P < 0.001). Conclusion: The characteristics of RE vary according to disease site among gastrointestinal enteral metallic stent placements. Thus, it is desirable to set DRL values based on the disease site.

3.
JGH Open ; 6(12): 833-838, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36514501

ABSTRACT

Background and Aim: Helicobacter pylori (H. pylori) eradication has become popular as it prevents the development of gastric cancer. There have been no comprehensive studies on advanced gastric cancer (AGC) after eradication; thus, the clinical characteristics remain unclear. This study aimed to compare the characteristics of AGC after eradication and with current H. pylori infection and evaluate the esophagogastroduodenoscopy (EGD) follow-up after eradication. Methods: This single-center, retrospective study included 261 consecutive patients diagnosed with AGC through EGD. The patients were grouped based on their H. pylori status: eradication (n = 48) and infection (n = 213) groups. Univariate analysis was conducted to compare clinicopathological characteristics between groups. The clinical course of the eradication group was analyzed by dividing the patients into three groups according to the interval from the last EGD until AGC detection: short-interval (<1 year), intermediate-interval (2-3 years), and long-interval (4-5 years) groups. Results: The radical resection (R0) rate was higher in the eradication group. In surgical cases, the median tumor diameter was shorter in the eradication group. Analysis of EGD surveillance after eradication in 36 available cases showed that 24 (66.7%) were detected within 5 years after eradication, and 3 (8.3%) were diagnosed as AGC > 20 years after eradication. The R0 rates in the short-, intermediate-, and long-interval groups were 83.3%, 71.4%, and 60%, respectively. Conclusions: AGC after eradication was more often detected at the phase in which R0 resection was possible. EGD follow-up with tight intervals of at least 5 years after eradication is advisable.

4.
Clin Endosc ; 55(5): 655-664, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35636748

ABSTRACT

BACKGROUND/AIMS: Endoscopic submucosal dissection (ESD) for residual or recurrent colorectal lesions after incomplete resection is challenging because of severe fibrosis. This study aimed to compare the efficacy of the pocket-creation method (PCM) with a traction device (TD) with that of conventional ESD for residual or recurrent colorectal lesions. METHODS: We retrospectively studied 72 patients with residual or recurrent colorectal lesions resected using ESD. Overall, 31 and 41 lesions were resected using PCM with TD and conventional ESD methods, respectively. We compared patient background and treatment outcomes between the PCM with TD and conventional ESD groups, respectively. The primary endpoints were en bloc resection and R0 resection rates. The secondary endpoints were the dissection speed and incidence of adverse events. RESULTS: En bloc resection was feasible in all cases with PCM with TD, but failed in 22% of cases of conventional ESD. The R0 resection rates for PCM with TD and conventional ESD were 97% and 66%, respectively. Dissection was significantly faster in the PCM with TD group (13.0 vs. 7.9 mm2/min). Perforation and postoperative bleeding were observed in one patient in each group. CONCLUSION: PCM with TD is an effective method for treating residual or recurrent colorectal lesions after incomplete resection.

5.
BMC Gastroenterol ; 22(1): 125, 2022 Mar 16.
Article in English | MEDLINE | ID: mdl-35296263

ABSTRACT

BACKGROUND: No studies have compared the performance of microvascular and microsurface patterns alone with their combination in patients undergoing magnifying endoscopy with narrow-band imaging for diagnosing gastric cancer. This study aimed to clarify the differences in diagnostic performance among these methods. METHODS: Thirty-three participating endoscopists who had received specialized training in magnifying endoscopy evaluated the microvascular and microsurface patterns of images of 106 cancerous and 106 non-cancerous lesions. If classified as "irregular," the lesion was diagnosed as gastric cancer. To evaluate diagnostic performance, we compared the diagnostic accuracy, sensitivity, and specificity of these methods. RESULTS: Performance-related items did not differ significantly between microvascular and microsurface patterns. However, the diagnostic accuracy and sensitivity were significantly higher when using a combination of these methods than when using microvascular (82.1% [76.4-86.7] vs. 76.4% [70.3-81.6] and 69.8% [60.5-77.8] vs. 63.2% [53.7-71.8]; P < 0.001 and P = 0.008, respectively) or microsurface (82.1% [76.4-86.7] vs. 73.6% [67.3-79.1] and 69.8% [60.5-77.8] vs. 52.8% [43.4‒62.1]; both, P < 0.001) patterns alone. The additive effect on diagnostic accuracy and sensitivity was 5.7‒8.6% and 6.6‒17.0%, respectively. CONCLUSIONS: We demonstrate the superiority of the combination of microvascular and microsurface patterns over microvascular or microsurface patterns alone for diagnosing gastric cancer. Our data support the use of the former method in clinical practice. Although a major limitation of this study was its retrospective, single-center design, our findings may help to improve the diagnosis of gastric cancer.


Subject(s)
Stomach Neoplasms , Endoscopy, Gastrointestinal , Humans , Narrow Band Imaging , Retrospective Studies , Stomach Neoplasms/diagnostic imaging
6.
Digestion ; 103(4): 261-268, 2022.
Article in English | MEDLINE | ID: mdl-35184058

ABSTRACT

INTRODUCTION: We aimed to investigate the safety and efficacy of self-expandable metallic stent (SEMS) placement in patients with prior radiotherapy (RT) using the Niti-S stent, which is characterized by low radial force, in comparison to patients without prior RT. METHODS: A consecutive series of 83 patients who were treated by SEMS placement using Niti-S stent for severe malignant esophageal obstruction or fistula were enrolled. The adverse event rates and efficacy were retrospectively compared between patients with/without prior RT before SEMS placement (RT group [n = 32] versus non-RT group [n = 51]). RESULTS: The incidence rate of major adverse events in the RT group was 6.3% and was not significantly different from that in the non-RT group (5.9%, p = 0.95). Among the RT group, 84.4% were able to resume oral intake within a median of 2 days. Among the patients with fistula, 78.6% could resume oral intake and survive for 73 days after SEMS placement. Cox proportional hazard regression analysis identified significant factors affecting overall survival to be prior RT (hazard ratio [HR]: 1.96), low performance status (HR: 3.87), and subsequent anticancer treatment after SEMS placement (HR: 0.41). However, compared to the non-RT group, the RT group had received longer duration of anticancer treatment before SEMS placement and a lower rate of subsequent anticancer treatment after SEMS placement. CONCLUSIONS: With the Niti-S stent, the incidence of major adverse events was sufficiently low even for patients after RT. SEMS with low radial force would be an effective palliative treatment option for patients, regardless of prior RT.


Subject(s)
Deglutition Disorders , Esophageal Stenosis , Self Expandable Metallic Stents , Deglutition Disorders/etiology , Deglutition Disorders/therapy , Esophageal Stenosis/etiology , Humans , Palliative Care , Retrospective Studies , Self Expandable Metallic Stents/adverse effects , Stents/adverse effects , Treatment Outcome
7.
Digestion ; 103(2): 159-168, 2022.
Article in English | MEDLINE | ID: mdl-34852348

ABSTRACT

INTRODUCTION: Although endocytoscopy (EC) with narrow-band imaging (NBI) is effective in diagnosing gastric cancer, no diagnostic system has been validated. We explored a specific diagnostic system for gastric cancer using EC with NBI. METHODS: Equal numbers of images from cancerous and noncancerous areas (114 images each) were assessed by endoscopists with (development group: 33) and without (validation group: 28) specific training in magnifying endoscopy with NBI. Microvascular and microsurface patterns (MS) in each image were evaluated. Lesions were diagnosed as cancerous when patterns were deemed "irregular." The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of a diagnosis according to patterns on EC with NBI (microvascular pattern [MV] alone, MS alone, and both) were evaluated and compared between groups to determine the diagnostic performance. RESULTS: In the development and validation groups, diagnoses based on the MV alone had significantly higher accuracy (91.7% vs. 76.3%, p < 0.0001 and 92.5% vs. 67.5%, p < 0.0001, respectively) and sensitivity (88.6% vs. 68.3%, p < 0.0001 and 89.5% vs. 38.6%, p < 0.0001, respectively) than those based on the MS alone. In both groups, there were no significant differences in diagnostic accuracy between using the MV alone and both patterns. DISCUSSION/CONCLUSION: Evaluation of the MV alone is a simple and accurate diagnostic method for gastric cancer. This system could find widespread applications in clinical practice.


Subject(s)
Stomach Neoplasms , Endoscopy, Gastrointestinal/methods , Humans , Narrow Band Imaging/methods , Predictive Value of Tests , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/pathology
8.
Dig Endosc ; 34(4): 793-804, 2022 May.
Article in English | MEDLINE | ID: mdl-34599604

ABSTRACT

OBJECTIVES: Endoscopic resection (ER) is indicated for a wide range of superficial esophageal squamous cell carcinomas (ESCCs). We examined the long-term outcomes in patients with pathological (p) invasion of ESCC into the T1a-muscularis mucosae (MM) and T1b-submucosa (SM) after ER, for which data on prognosis are limited. METHODS: Of the 1217 patients with superficial ESCC who underwent ER, 225 patients with a pathological diagnosis of ESCC invasion into the MM, minute submucosal invasion ≤200 µm (SM1), or massive submucosal invasion (SM2) were included. In patients with lymphovascular invasion, droplet infiltration, or SM2 invasion, additional treatments, including chemoradiation (CRT) or esophagectomy with two- to three-field lymph node dissection, were recommended. The median observation period was 66 months (interquartile range 48-91 months). RESULTS: In total, there were 151, 28, and 46 pT1a-MM, pT1b-SM1, and pT1b-SM2 cases, respectively. Metastatic recurrence was observed in 1.3%, 10.7%, and 6.5% patients with pT1a-MM, pT1b-SM1, and pT1b-SM2 ESCCs, respectively. Of the eight patients with metastatic recurrence, six were successfully treated, and two died of ESCC. The 5-year overall survival rates were 84.1%, 71.4%, and 67.4%, the 5-year relapse-free survival rates were 82.8%, 64.3%, and 65.2%, and the 5-year disease-specific survival rates were 100%, 96.4%, and 99.1% in patients with pT1a-MM, pT1b-SM1, and pT1b-SM2 ESCCs, respectively. Multivariate analysis showed that additional CRT and esophagectomy, and T1b-SM2 were positively and negatively associated with overall survival, respectively. CONCLUSIONS: Endoscopic resection preceding appropriate additional treatments resulted in favorable outcomes. Many cases of metastatic recurrence in this cohort could be successfully treated.


Subject(s)
Esophageal Neoplasms , Esophageal Squamous Cell Carcinoma , Esophageal Neoplasms/surgery , Esophageal Squamous Cell Carcinoma/surgery , Esophagectomy/adverse effects , Esophagoscopy/methods , Humans , Mucous Membrane/pathology , Mucous Membrane/surgery , Neoplasm Recurrence, Local/pathology , Retrospective Studies , Treatment Outcome
9.
Endoscopy ; 53(11): 1105-1113, 2021 11.
Article in English | MEDLINE | ID: mdl-33540446

ABSTRACT

BACKGROUND: It is known that an esophagus with multiple Lugol-voiding lesions (LVLs) after iodine staining is high risk for esophageal cancer; however, it is preferable to identify high-risk cases without staining because iodine causes discomfort and prolongs examination times. This study assessed the capability of an artificial intelligence (AI) system to predict multiple LVLs from images that had not been stained with iodine as well as patients at high risk for esophageal cancer. METHODS: We constructed the AI system by preparing a training set of 6634 images from white-light and narrow-band imaging in 595 patients before they underwent endoscopic examination with iodine staining. Diagnostic performance was evaluated on an independent validation dataset (667 images from 72 patients) and compared with that of 10 experienced endoscopists. RESULTS: The sensitivity, specificity, and accuracy of the AI system to predict multiple LVLs were 84.4 %, 70.0 %, and 76.4 %, respectively, compared with 46.9 %, 77.5 %, and 63.9 %, respectively, for the endoscopists. The AI system had significantly higher sensitivity than 9/10 experienced endoscopists. We also identified six endoscopic findings that were significantly more frequent in patients with multiple LVLs; however, the AI system had greater sensitivity than these findings for the prediction of multiple LVLs. Moreover, patients with AI-predicted multiple LVLs had significantly more cancers in the esophagus and head and neck than patients without predicted multiple LVLs. CONCLUSION: The AI system could predict multiple LVLs with high sensitivity from images without iodine staining. The system could enable endoscopists to apply iodine staining more judiciously.


Subject(s)
Esophageal Neoplasms , Esophageal Squamous Cell Carcinoma , Artificial Intelligence , Esophageal Neoplasms/diagnostic imaging , Esophagoscopy , Humans , Narrow Band Imaging
10.
Gastric Cancer ; 24(2): 417-427, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33011866

ABSTRACT

BACKGROUND: For diagnosing gastric cancer, differences in the diagnostic performance between endocytoscopy with narrow-band imaging and magnifying endoscopy with narrow-band imaging have not been reported. We aimed to clarify these differences by analyzing diagnoses made by endoscopists in Japan. METHODS: This single-center retrospective cohort study used 106 cancerous and 106 non-cancerous images obtained via both modalities (total, 424 images) for diagnosis. Sixty-one endoscopists with varying experience levels from 45 institutions were included. Diagnostic accuracy, sensitivity, specificity, and positive and negative predictive values were evaluated to determine the diagnostic performance of each modality and compared using the Mann-Whitney U test. RESULTS: Among all endoscopists, diagnostic accuracy, sensitivity, positive predictive value, and negative predictive value were higher with endocytoscopy with narrow-band imaging than with magnifying endoscopy with narrow-band imaging (percentage [95% confidence interval]: 78.8% [76.4-83.0%] versus 72.2% [69.3-73.6%], p < 0.0001; 82.1% [78.3-85.9%] versus 64.2% [60.4-69.8%], p < 0.0001; 88.7% [82.6-90.7%] versus 78.5% [75.4-85.1%], p = 0.0023; 79.0% [75.3-80.5%] versus 68.5% [66.4-71.6%], p < 0.0001, respectively). In the magnifying endoscopy with narrow-band imaging-trained group, these values were also higher with endocytoscopy with narrow-band imaging than with magnifying endoscopy with narrow-band imaging (p < 0.0001, p = 0.0001, p = 0.0143, and p < 0.0001, respectively). Diagnostic accuracy, sensitivity, and negative predictive value were higher with endocytoscopy with narrow-band imaging than with magnifying endoscopy with narrow-band imaging in the magnifying endoscopy with narrow-band imaging-untrained group (p = 0.0041, p = 0.0049, and p = 0.0098, respectively). CONCLUSIONS: Diagnostic performance was higher using endocytoscopy with narrow-band imaging than using magnifying endoscopy with narrow-band imaging. Our results may help change the technique used to diagnose gastric cancer.


Subject(s)
Early Detection of Cancer/statistics & numerical data , Endoscopy, Gastrointestinal/statistics & numerical data , Narrow Band Imaging/statistics & numerical data , Radiographic Magnification/statistics & numerical data , Stomach Neoplasms/diagnosis , Case-Control Studies , Clinical Competence , Early Detection of Cancer/methods , Endoscopy, Gastrointestinal/methods , Humans , Japan , Narrow Band Imaging/methods , Predictive Value of Tests , Radiographic Magnification/methods , Retrospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...